+353 86 125 4160 ldecobuilding@gmail.com


Boiler problems can depart you devoid of very hot drinking water and switch off your central heating when you the very least count on it. Fortunately, present day Vaillant boilers use mistake codes to signal a fault. These give you a way to examine the severity of the dilemma, and they make troubleshooting an less complicated approach. A Vaillant boiler F22 fault code is among the most commonly searched on the net. This report guides you as a result of what this code indicates, what you can potentially do about it, and when to call a Gasoline Safe and sound-registered engineer.

What does the Vaillant F22 mistake code stand for?

An F22 fault comes about when there is much too minor water pressure for your boiler to hearth up. Which is why, if you’re searching at a Vaillant F22 fault code, your boiler is possibly ‘locked out’, and there is no very hot drinking water coming from your faucets or shower. You’ll also discover that your radiators will not be warming up as expected.

In addition to this code, you may recognize that a amount these types of as .3 flashes up on your boiler’s screen. This is the force degree inside the system, which really should usually be all-around 1.5 bar relying on the design. You could also look at the tension gauge if you have 1 to corroborate the problem.

Suggestion: The encouraged stress stage can vary involving Vaillant boiler versions. Please look at your boiler’s manual to locate this data.

Vaillant F22 Fault Code

Why does my boiler have small drinking water strain?

Boilers can eliminate tension for a number of causes. These involve age, leaks in the pipework or a broken expansion vessel or tension release valve. You may also notice force drops if you have a short while ago bled your radiators. Nevertheless, most Vaillant boiler F22 faults materialize because air gets into the process. As such, you may possibly have to leading the tension up every 6 months or so.

Notice that this is a gradual drop and not anything that takes place right away. If you have a unexpected loss of pressure or have to top the boiler’s stress amount up every single handful of months, it usually means there is an fundamental concern.

How can I appropriate pressure problems in my Vaillant boiler?

You can try out to repressurise your boiler if you are assured that you can do it appropriately and safely and securely. To do this, you will want to switch the valves linked to every single end of the boiler’s filling loop. This may possibly take away the F22 code and restore your program to standard, but please be aware that you should not have to do this far more than once or 2 times a year.

  1. Test your exhibit to make sure it’s an F22 code
  2. Find the two valves, normally found beneath the boiler
  3. Rotate the proper valve 90 degrees, then slowly and gradually rotate the still left valve
  4. Enjoy the boiler’s show to make sure the pressure bar rises
  5. The moment the pressure’s between 1.2 and 1.5 bar, close both of those valves
  6. You may perhaps have to reset your boiler if the F22 code continue to appears

This entire approach ought to only choose a couple seconds. Make confident you near equally valves when the stress reaches the great degree, ideally no increased than 1.5 bar for a cold system. This is mainly because your boiler will raise the strain after it fires up, so you can expect your display to browse nearer to 2 bar. If it receives increased than 2.5 bar, you might have above-pressurised the procedure.

Suggestion: Increased the pressure by also a lot? Don’t stress! You can lessen it by bleeding your radiators and checking the boiler force following bleeding each individual 1. We have a guide on how you can bleed a radiator on your own, but if you like, you can usually get us to do it for you. We could also inspect your boiler for underlying concerns.

Down below: An example of a filling loop underneath a combi boiler. If you have a method or warmth only boiler, your filling loop may well be connected to the pipework or attached to an external expansion vessel. 

Vaillant Boiler F22 Fault Code

What if the F22 arrives back in a 7 days or two?

If the code returns before long following topping the force up, it is time to get in touch with in a Gas Protected-registered engineer. They will look at the boiler for ruined parts, and if they locate the supply of the difficulty, they can then provide the boiler repairs you will need. If your engineer just cannot obtain a fault on the boiler, a leak is the most very likely difficulty.

We have fuel engineers who are qualified and geared up for leak detection. If they just can’t come across a fault on your boiler, or a leak on the exposed elements of your central heating method, they can start out the non-invasive detection course of action on hid pieces of your technique ideal away. This avoids scheduling one more appointment. Remember to notice, our leak detection company is executed at a different 50 percent-hour amount to gasoline do the job.

Significant! You ought to by no means test to make the repairs oneself. Carrying out so could induce big damage to your boiler, and you could enhance the hazard of carbon monoxide poisoning. Fuel Protected heating engineers are educated to perform with heating programs, and generally within just HSE regulations.

How can I steer clear of getting a Vaillant boiler F22 mistake code?

Boiler challenges can transpire out of the blue and for a lot of explanations, so it’s difficult to safeguard towards them – and this applies to all helps make and models. The best matter you can do is keep up to date with your servicing agenda. A annually boiler support is envisioned by home insurance policy corporations, and without the need of it, you could reduce your manufacturer’s assure.

Did you know? Yearly servicing may lower your gas usage by up to 30%. Your engineer can verify that your boiler’s established to the suitable temperature and that it is burning gasoline successfully. If it is not, they can make some tweaks to optimise its overall performance.

Aspect can get to the coronary heart of any Vaillant boiler difficulty, irrespective of whether it is due to inadequate water stress, a free link or a damaged part. We’re even users of the Vaillant Advance approved installer scheme, so we’re equipped to offer the special tips, set up and servicing perform you’d assume from a Vaillant expert. Whatever the fault code, we’ll deal with the issue as rapidly as doable, for a heat and vitality-economical home all 12 months round.